What is a PowerFlex AC drive?
PowerFlex® Compact-class AC Drives deliver a simple and cost-effective solution for standalone machine level control applications or simple system integration. Designed for ease of use, this general-purpose class of drives provides a compact package to optimize panel space and application versatility.
What is PowerFlex 700?
The PowerFlex 700 AC drive is designed to control three-phase induction motors in applications with requirements ranging from the simplest speed control to the most demanding torque control. The drive has volts per hertz, sensorless vector and vector control.
Is PowerFlex 700 obsolete?
Rockwell Automation announces that as of April 30, 2017, the PowerFlex® 700 AC high power drives (250… 700 Hp, 160…500 kW) are discontinued and no longer available for sale.
How do I update my PowerFlex 755 firmware?
With the PowerFlex 755 drive selected, click Flash Update. 6. From the list of available devices, select the PowerFlex 755 drive and click Next >. Flash updating the device firmware may cause the device to load defaults.
How do I update my PowerFlex 525 firmware?
- Select the entry of the PowerFlex 525 drive you are updating and click OK.
- Select the firmware revision you want to flash and click Next.
- Follow the remaining prompts to complete the flash update. When the.
What is the PowerFlex 700 adjustable frequency AC drive manual?
The purpose of this manual is to provide you with the basic information needed to install, start-up and troubleshoot the PowerFlex 700 Adjustable Frequency AC Drive. This manual is intended for qualified personnel. You must be able to program and operate Adjustable Frequency AC Drive devices.
What kind of power supply do I need for PowerFlex 700?
PowerFlex 700 Adjustable Frequency AC Drive – Frames 7…10 Auxiliary Control Power Supply If desired, an auxiliary control power supply can be used with certain drives to keep the drive control logic up when the main AC power is removed.
How do I clear the fault on a PowerFlex 700?
After corrective action has been taken, clear the fault by one of these methods: • Press Stop • Cycle drive power • Set parameter 240 [Fault Clear] to “1.” • “Clear Faults” on the Human Interface Module (HIM) Diagnostic menu. Esc Rockwell Automation Publication 20B-IN019E-EN-P – July 201377 PowerFlex 700 Adjustable Frequency AC Drive – Frames 0…6
How do I run an assisted start-up on a PowerFlex 700?
70Rockwell Automation Publication 20B-IN019E-EN-P – July 2013 PowerFlex 700 Adjustable Frequency AC Drive – Frames 0…6 Running an Assisted Start Up The Assisted start-up routine prompts you to input required information. Access Assisted Start Up by selecting “Start Up” from the Main Menu. To perform an Assisted Start-Up Drive Status Indicators